Our current list of automated calibration procedures that are either completed or near completion with development. All the programs listed below are customizable or can be purchased as is.
Status:
- Ready: Fully tested and ready for purchase and deployment.
- Ready-pending update: Fully tested and ready for sale but it in the update queue for V3 upgrades.
- Final Testing: Requires final testing before production release
- Update Required: Program requires V3 upgrade to enable remote support for clients outside local service area.
Platform Version:
- V1: No error reporting, no remote support, no auto-detect and audible features.
- V2: Basic error reporting, very limited remote support, includes auto-detect and audible features
- V3: Current revision with enhanced error reporting, enhanced remote support, produced with advanced internally developed tools and with smaller/efficient code base for high speed development.
- V4 (COMING SOON!): This version will be one program loaded with all the test procedures we developed with flexible pricing; “Pay as you go” or purchase a permanent license for a procedure. Modular design to include special tools like pulling trace data from a Network Analyzer or monitoring a USB power sensor. Integration friendly to save test data to customer’s calibration management software.
Derived Procedure:
- Manufacturer: Procedure is based on a manufacturer procedure of the unit under test and may also be based on the manufacturer datasheet. See program readme.txt for exact revision of documentation used.
- Internal: Procedure is based on an internally produced procedure and portions may be sourced from government, custom specifications, and/or generally accepted test methods.
Manufacturer | Model | Required Standards | Status | Platform Version | Derived Procedure |
---|---|---|---|---|---|
Agilent | 33120A | Keysight 8482A power sensor, Keysight E441XA power meter, Agilent 3458A | Ready | V2 | Manufacturer |
Agilent | 33220A | Keysight 8482A power sensor, Keysight E441XA power meter, Agilent 3458A | Ready | V2 | Manufacturer |
Agilent | 33250A | Keysight 8482A power sensor, Keysight E441XA power meter, Agilent 3458A, Agilent 5313XA frequency counter | Ready | V2 | Manufacturer |
Agilent | 34401A | Fluke 5520A or 5522A or 5700A calibrators | Ready-pending update | V1 | Manufacturer |
Agilent | EPM Series | Keysight 8482A power sensor, Keysight E441XA power meter, Agilent 3458A | Update Required | V2 | Internal |
Agilent | Programmable Attenuators | HP 11713A switch driver, Keysight E8362C Network Analyzer and 85052B, 85054B, 85056D calibration kits | Ready | V3 | Internal |
Any | Fixed attenuators | Agilent E8362B/C Network Analyzer and 85052B, 85054B, 85056D calibration kits | Ready | V3 | Internal |
Any | Directional Couplers | Agilent E8362B/C Network Analyzer and 85052B, 85054B, 85056D calibration kits | Ready | V3 | Internal |
Any | RF Amplifiers | Agilent E8362B/C Network Analyzer and 85052B, 85054B, 85056D calibration kits | Ready | V3 | Internal |
Ectron | 1140A | Fluke 5522A/5520A Calibrator, Agilent 3458A | Ready | V2+ | Manufacturer |
Fluke | 5500A | Fluke 5790A, HP 53131/2A Counter w/ ch3, Fluke 8508A, HP 3458A, Fluke 5700A, Clarke-Hess 6000A, Agilent E444XA, E4419AB or N191XA power meter, E9304A 8491D and 8482A power sensors, Agilent DSO81004A, HP 4284A LCR Meter, Fluke 742A-100, 742-10, 742-1, A40B-10A and A40B-10mA shunts | Update Required | V2 | Manufacturer |
Fluke | 5522A | Fluke 5790A, HP 53131/2A Counter w/ ch3, Fluke 8508A, HP 3458A, Fluke 5700A, Clarke-Hess 6000A, Agilent E444XA, E4419AB or N191XA power meter, E9304A 8491D and 8482A power sensors, Agilent DSO81004A, HP 4284A LCR Meter, Fluke 742A-1k, 742A-100, 742-10, 742A-1, A40B-20A, A40B-10A, A40B-200mA, A40B-100mA, A40B-20mA, A40B-10mA shunts, Capacitor standards: 5pF, 29pF, 49pF and Resistor standards: 40, 50, 60, 600K, 1M and 1.5M ohm. | Ready-pending update | V2 | Manufacturer |
Fluke | 5700A | Fluke 8508A, HP 3458A, Fluke 5790A, Agilent 53131/2A, Fluke precision shunts. | Update Required | V1 | Manufacturer |
Keithley | 2400 | Fluke 5522A or 5520A calibrator and Keysight 3458A Digital Multimeter. | Ready | V3 | Manufacturer |
Keithley | 2410 | Fluke 5522A or 5520A calibrator and Keysight 3458A Digital Multimeter. | Ready | V3 | Manufacturer |
Keithley | 2420 | Fluke 5522A or 5520A calibrator and Keysight 3458A Digital Multimeter. | Final Testing | V3 | Manufacturer |
Keithley | 2425 | Fluke 5522A or 5520A calibrator and Keysight 3458A Digital Multimeter. | Final Testing | V3 | Manufacturer |
Keithley | 2430 | Fluke 5522A or 5520A calibrator and Keysight 3458A Digital Multimeter. | Final Testing | V3 | Manufacturer |
Keithley | 2440 | Fluke 5522A or 5520A calibrator and Keysight 3458A Digital Multimeter. | Final Testing | V3 | Manufacturer |
Keysight | 33521A | Fluke 5522A or 5520A calibrator and Keysight 3458A Digital Multimeter. | Final Testing | V3 | Manufacturer |
Keysight | 33522A | Fluke 5522A or 5520A calibrator and Keysight 3458A Digital Multimeter. | Final Testing | V3 | Manufacturer |
Keysight | 33509B | Fluke 5522A or 5520A calibrator and Keysight 3458A Digital Multimeter. | Final Testing | V3 | Manufacturer |
Keysight | 33510B | Fluke 5522A or 5520A calibrator and Keysight 3458A Digital Multimeter. | Final Testing | V3 | Manufacturer |
Keysight | 33511B | Fluke 5522A or 5520A calibrator and Keysight 3458A Digital Multimeter. | Final Testing | V3 | Manufacturer |
Keysight | 33512B | Fluke 5522A or 5520A calibrator and Keysight 3458A Digital Multimeter. | Final Testing | V3 | Manufacturer |
Keysight | 33519B | HP 3458A, Agilent 53131/2A counter, EPM or N191XA power meter with appropriate power sensor OR Fluke 5790A. | Final Testing | V3 | Manufacturer |
Keysight | 33520B | HP 3458A, Agilent 53131/2A counter, EPM or N191XA power meter with appropriate power sensor OR Fluke 5790A. | Final Testing | V3 | Manufacturer |
Keysight | E8257D | Agilent E444XA PSA, Agilent EPM power meter with E9304A and 8487A and10MHz standard reference. | Update Required | V2 | Internal |
Keysight | ECAL | Keysight E8362B or E8364C | Ready-pending update | V2 | Internal |
Keysight | N191XA | Keysight 8482A power sensor, Keysight E441XA power meter, Agilent 3458A | Ready | V3 | Internal |
Keysight | N522XA | Agilent EPM power meter with E9304A and 8487A sensors, Agilent 53131/2A counter, Calibration kit, Fluke 9640A | Update Required | V1 | Internal |
Rohde and Schwarz | SMA100A-B | Agilent E4440A, Agilent 53131/2A, Agilent N191XA, Agilent N5532A Opt 504 & 518, HP 3458A, HP 8903B, Agilent Infiniium Oscilloscope | Ready | V3 | Internal |
Rohde and Schwarz | SMB100A/B | Agilent E444XA spectrum analyzers, Agilent 53131/2A counter, Agilent N191XA power meter, HP 3458A DMM, HP 8903B audio analyzer, Agilent Infiniium oscilloscope (for option K22), N5532A/B power sensor w/opt 504 and 518. | Ready | V3 | Internal |
Rohde and Schwarz | SMBV100A-B | Agilent E4440A (Opt BJ7 required for WCDMA), Agilent 53131/2A, Agilent N191XA, Agilent N5532A Opt 504 & 518, HP 3458A, HP 8903B, Agilent Infiniium Oscilloscope | Ready | V3 | Internal |
Rohde and Schwarz | SMW200A | Agilent E4440A, Agilent 53131/2A, Agilent N191XA, Agilent N5532A Opt 504 & 550, HP 3458A, HP 8903B | Ready | V3 | Internal |
Tektronix | PA3000 | Fluke 5522A or 5520A calibrator. | Ready | V3 | Manufacturer |
Tektronix | PA4000 | Fluke 5522A or 5520A calibrator. | Ready | V3 | Manufacturer |
Voltech | PM1000 | Fluke 5522A or 5520A calibrator. | Update Required | V1 | Manufacturer |
Voltech | PM3000A (ACE Version only) | Fluke 5520A or 5522A calibrator | Ready | V2 | Manufacturer |
Voltech | PM6000 | Fluke 5520A or 5522A calibrator | Ready | V2 | Manufacturer |
Xitron | 2801/2802 | Fluke 5520A or 5522A calibrator | Ready | V3 | Manufacturer |
Yokogawa | WT1800 | Fluke 5520A or 5522A calibrator | Ready-pending update | V2 | Manufacturer |
Yokogawa | WT1800E | Fluke 5520A or 5522A calibrator | Ready | V3 | Manufacturer |
Yokogawa | WT3000 | Fluke 5520A or 5522A calibrator | Ready | V3 | Manufacturer |
Yokogawa | WT5000 | Fluke 5522A calibrator. Optional:Fluke 5730A Calibrator, HP 3458A DMM, Fluke A40B Shunts | Ready | V3 | Manufacturer |